PD-169 Issue 3B Installation Guide Page 26 of 56
TONE – Re-assurance Tone
To conform to DDA requirements the controller provides a re-assurance tone when a phone
is ringing and also when the door lock has been operated from the door panel or the called
phone, but not the exit button. In some situations these tones can be considered a nuisance
and therefore can be turned off.
Four settings are available: -
[Both] = Ringing and lock tones.
[Call] = Ringing tone only.
[Lock] = Lock tone only.
[None] = No tones.
CANC – Not used, leave on the Default of [Yes]
BCAL – Not used, leave on the Default of [No]
12A? – Flat 13 Numbered as 12A
For use when flat numbering is 11, 12, 12A, 14, 15 When set to [Yes] entering “12A
callwill actually send “13so that the DBA-4I/8Z’s can be set to respond to 11, 12, 13,
14, 15
BSD-DIG Door Controller Jumper Settings
All the jumpers apply to video systems only, so settings have no effect.